Drive Slot Sensor For Storage Drive Fault Was Deasserted

  1. Storage Drive 3 Drive Slot Sensor For Storage Drive Fault Was Asserted
  2. Drive Slot Sensor For Storage Drive Fault Was Asserted
Storage drive 2 drive slot sensor for storage drive fault was asserted

Good question...

I did a couple of searches and this came up... sounded fairly similar to your instance and might be worth a try.

Dec 12, 2013  Hi, There is a chance that the hard disk is getting predictive failures. You can verify this by opening KVM, reboot server, press ESC at Cisco splash screen, then during POST press CTRL+C to access LSI Config Utility, go to RAID properties and check if any of the HDDs have 'Yes' under 'Pred Fail'. Aug 15, 2013  its always good read the new raid firmware change log and update it in case it has an issue that affect you. Agree with Martin. I had 4 PE2900 that after 2-3 years had the same issue, bought new battery and replaced it and was ok.

'One of our 2950s ambered with the E1211 ROMB BATT error, but OpenManage displayed no error, other than the log was full of: Storage ROMB Battery: Battery sensor for Storage, failed was deasserted, Storage ROMB Battery: Battery sensor for Storage, failed was asserted entries logged every 5-30 seconds and the LCD would amber and return to blue with every assertion/deassertion. We powered it down, powered it up - same error. I powered it down, replaced the PERC battery, but the behavior continued. Replacing the battery fixed the issue in another 1950/2950 that was having the same issues a year or two ago, but not this time.

Storage Drive 3 Drive Slot Sensor For Storage Drive Fault Was Asserted

What did fix it was starting the battery learn cycle in OpenManage: System - Storage - PERC 5/i Integrated - Battery, Battery Tasks - Start Learn Cycle. The logs stopped, the learn cycle started and completed normally.'

Drive Slot Sensor For Storage Drive Fault Was Asserted

Hopefully this helps.